Description

Overview

ARI FABA® Fig. 45.046 (from manufacturer datasheet 040001, Edition 12/10) is a stop valve with bellows seal, straight through with flanges, in forged steel. The body and bonnet are P250GH, 1.0460, nominal pressure PN40, nominal size range DN15–DN50. For sizes above DN50 the datasheet refers to Fig. 35.046 in 1.0619+N cast steel.

Applications listed in the datasheet: industry, power stations, flue gas purification plant, processing technology, gas supply, vapour facilities, recycling facilities, vacuum facilities, hot water, heating technology, district heating, thermal oil applications and general plant manufacturing. Flow media: steam, gases, hot water, thermal oil, process water, vacuum facilities, ammonia and others on request.

Features

  • Bellows seal, double wall, X6CrNiMoTi17 12 2, 1.4571
  • Throttling plug as standard (for max. permissible ΔP refer to flow diagram)
  • Secondary sealing by pure graphite packing ring
  • Tests: TÜ.A/TÜV.AR.186-00 approvals
  • German TA - Luft TÜV-Test-No. 088-945053
  • A production allowance acc. to TRB 801 No. 45 exists

Technical data

  • Type: bellows sealed stop valve, straight through, flanged
  • Figure: Fig. 45.046
  • Nominal pressure: PN40
  • Nominal size: DN15–DN50
  • Body material: P250GH, 1.0460 (forged steel)
  • Seat: G19 9 NbSi, 1.4551
  • Bellows seal: X6CrNiMoTi17 12 2, 1.4571
  • Stem: X20Cr13+QT, 1.4021+QT
  • Face-to-face dimension: FTF series 1 acc. to DIN EN 558
  • Standard flanges: acc. to DIN EN 1092-1/-2 (flange holes / thickness tol. acc. to DIN 2533/2544/2545)

Parts and materials

Datasheet parts table for Fig. 45.046 reproduced in full (* = spare part):

Pos.DescriptionFig. 45.046
1BodyP250 GH, 1.0460
1.2SeatG19 9 NbSi, 1.4551
2BonnetP250 GH, 1.0460
3Plug *X20Cr13+QT, 1.4021+QT
4.1Bellows seal *X6CrNiMoTi17 12 2, 1.4571
4.2Stem *X20Cr13+QT, 1.4021+QT
5HandwheelFe P01, 1.0330 (epoxy-coating)
6Packing ring *Pure graphite
7Stud25CrMo4, 1.7218
8Hexagon nutC35E, 1.1181
9Gasket *Pure graphite (CrNi laminated with graphite)

Dimensions and weights

Datasheet page 3, tables reproduced in full (face-to-face dimension FTF series 1 according to DIN EN 558):

ItemDN15DN20DN25DN32DN40DN50
L (mm)130150160180200230
H1 (mm)215215225230225230
ØC (PN40) (mm)126126126126150150
Travel (mm)66881313
Kvs-value (m³/h)3,35,89,21523,336
Zeta-value—7,47,67,47,47,5
Weight 45.046 (kg)3,84,85,571012

Zeta-value: range of tolerance for Kvs-values acc. to VDI/VDE 2173. Standard-flange dimensions refer to the datasheet page 15 (flanges acc. to DIN EN 1092-1/-2).

Plug design and differential pressure limits

At differential pressures exceeding the following values, the stop valve must be fitted with a pressure balancing plug (datasheet page 13):

DN125150200250300350400500
Differential pressure ΔP (bar)252114964,53,51,5

Plug designs listed in the datasheet: regulating plug, regulating plug with soft seal (max. operating temperature 200 °C at PTFE + 25 % carbon), screw down non-return plug, plug with marginal seat, isolation plug with marginal seat (stellited seat and plug). Valves with balancing plugs are installed with the medium flowing over the plug as indicated by the flow direction arrow on the valve body; balancing plugs are fully effective only in closed systems.

Accessories

Accessories listed on datasheet page 14: limit switch, hood valve (tamper resistant handwheel cover), chain wheel, stem extension (please specify height in your order), travel limiter, lubricating nipple and locking device (standard: lubricating nipple, locking device; accessories are not included).

Ordering information

Please indicate when ordering: figure no., nominal pressure, nominal diameter and special design or accessories.

Specify Fig. 45.046, DN, PN, and quantity when requesting a quotation.